Regulated Power Supply, 100-240V AC, 12V 10 A, single phase, Optimized
Main
range of product : Modicon Power Supply
product or component type : Power supply
power supply type : Regulated switch mode
variant option : Optimized
enclosure material : Aluminium
Nominal input voltage
: 100...240 V AC single phase
: 00...240 V AC 2 phases
: 140...340 V DC
input voltage limits
: 85...264 V AC
: 120...375 V DC
rated power in W : 120 W
output voltage : 12 V DC
power supply output current : 10 A
Complementary
Nominal network frequency : 50…60 Hz
Network system compatibility
: TN
: TT
: IT
maximum leakage current1 mA : 240 V AC
input protection type
: Integrated fuse (not interchangeable) 4 A
: External protection (recommended) 20 A Curve C
: External protection (recommended) 13 A Curve C
inrush current
: 30.0 A at 115 V
: 60.0 A at 230 V
power factor
: 0.55 at 115 V AC
: 0.45 at 230 V AC
efficiency
: 84 % at 115 V AC
: 86 % at 230 V AC
Output voltage adjustment : 11...14 V
power dissipation in W : 25 W
current consumption
: < 2.5 A 115 V AC
: < 1.4 A 230 V AC
: < 1.3 A 140 V DC
Turn-on time : < 1 s
holding time
: > 20 ms 115 V AC
: > 40 ms 230 V AC
Startup with capacitive loads : 8000 µF
residual ripple : < 120 mV
Expected capacitor life time : 10 year(s)
meantime between failure [MTBF] : 700000 h at 25 °C, full load conforming to SR 332
output protection type
: Against overload and short-circuits, protection technology: automatic reset
: Against over temperature, protection technology: manual reset
: Against overvoltage, protection technology: manual reset
connections - terminals
: Screw connection: 0.5...4 mm², (AWG 20...AWG 12) without wire end ferrule for output
: Screw connection: 0.5...2.5 mm², (AWG 20...AWG 14) with wire end ferrule for output
: Screw connection: 0.75...4 mm², (AWG 18...AWG 12) without wire end ferrule for input
: Screw connection: 0.75...4 mm², (AWG 18...AWG 12) with wire end ferrule for input
line and load regulation
: < 0.5 %line
: < 1 %load
status LED : 1 LED (green)output voltage
depth : 117.6 mm
height : 123.6 mm
width : 40 mm
net weight : 0.52 kg
output coupling
: Parallel
: Serial
mounting support
: Top hat type TH35-15 rail conforming to IEC 60715
: Top hat type TH 35-7.5 rail conforming to IEC 60715
: Double-profile DIN rail
supply
: SELV conforming to EN/IEC 60950-1
: SELV conforming to EN/IEC 60204-1
: SELV conforming to IEC 60364-4-41
Environment
standards
: EN 62368-1
: EN/IEC 61010-1
: EN 61010-2-201
: EN/IEC 61204-3
: EN 61000-6-1
: EN 61000-6-2
: EN 61000-6-3
: EN 61000-6-4
: EN 61000-3-2
: EN 61000-3-3
: UL 62368-1
: UL 61010-1
: UL 61010-2-201
: CSA C22.2 No 62368-1
: CSA C22.2 No 61010-1
: CSA C22.2 No 61010-2-201
: EN/IEC 62368-1
product certifications
: CE
: CUL listed
: CUL recognized
: RCM
: CB Scheme
: EAC
: KC
environmental characteristic : 3M4 conforming to IEC 60721-3-3
operating altitude : < 5000 m
shock resistance : 100 m/s² for 11 ms
IP degree of protection : IP20
ambient air temperature for operation
: -20…-10 °C (with current derating of 2 % per °C)
: 40…70 °C (with current derating of 1.8 % per °C)
: 50…70 °C (with current derating of 2.5 % per °C)
ambient air temperature for storage : -40…85 °C
relative humidity : 0…95 % without condensation
overvoltage category : II
electrical energy source class conforming to IEC 62368-1 : ES1
electrical shock protection class : Class I
pollution degree : 2
vibration resistance
: 3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6
: 10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6
Electromagnetic immunity
: Immunity to electrostatic discharge - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
: Immunity to electrostatic discharge - test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2
: Immunity to conducted RF disturbances - test level: 10 V/m (80 MHz...2 GHz) conforming to EN/IEC 61000-4-3
: Immunity to conducted RF disturbances - test level: 5 V/m (2...2.7 GHz) conforming to EN/IEC 61000-4-3
: Immunity to conducted RF disturbances - test level: 3 V/m (2.7...6 GHz) conforming to EN/IEC 61000-4-3
: Immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4
: Surge immunity test - test level: 3 kV (between power supply and earth) conforming to EN/IEC 61000-4-5
: Surge immunity test - test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5
: Immunity to conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
: Immunity to magnetic fields - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8
: Immunity to voltage dips conforming to EN/IEC 61000-4-11
: Disturbing field emission conforming to EN 55016-2-3
: Limits for harmonic current emissions conforming to EN 61000-3-2
: Conducted disturbance emission conforming to EN 55016-1-2
: Conducted disturbance emission conforming to EN 55016-2-1
electromagnetic emission
: Conducted emissions conforming to EN 61000-6-3
: Radiated emissions conforming to EN 61000-6-4
dielectric strength : 3000 V AC input to output